Our THC Series thru-hole load cells offer an
outside
diameter of 2.00 inches and up to six
different thru-hole diameter options
per capacity
range. These load cells are manufactured from heat
treated 17-4 ph stainless
steel. The sensing element
incorporates bonded foil strain gages of the
highest
quality and are sealed for protection against most
industrial
environments.
Order Code Model
Capacity Range
Description
Price
Quantity
Add to Cart
THC-500-P
Capacity: 500 lbs
Thru Hole Load Cell
$545
THC-1K-P
Capacity: 1,000 lbs
Thru Hole Load Cell
$545
THC-2K-P
Capacity: 2,000 lbs
Thru Hole Load Cell
$545
THC-3K-P
Capacity: 3,000 lbs
Thru Hole Load Cell
$545
THC-5K-P
Capacity: 5,000 lbs
Thru Hole Load Cell
$545
THC-7.5K-P
Capacity: 7,500 lbs
Thru Hole Load Cell
$545
THC-10K-P
Capacity: 10,000 lbs
Thru Hole Load Cell
$545
SPECIFICATIONS
Rated Output (R.O.):
2 mV/V nominal
Nonlinearity:
0.25% of R.O.
Hysteresis:
0.25% of R.O
Nonrepeatability:
0.1% of R.O.
Zero Balance:
1.0% of R.O.
Compensated Temp. Range:
60° to 160°F
Safe Temp. Range:
-65° to 200°F
Temp. Effect on Output:
0.005% of Load/°F
Temp. Effect on Zero:
0.01% of R.O./°F
Terminal Resistance:
350 ohms nominal
Excitation Voltage:
10 VDC
Safe Overload:
150% of R.O.
Deflection Inches:
0.002 @ R.O.
MODEL
CAPACITY
LBS.
AVAILABLE INSIDE
HOLE DIAMETER
THC-250
250 LBS.
-P, -Q, -R, -S, -T, -V
THC-500
500 LBS.
-P, -Q, -R, -S, -T, -V
THC-1K
1,000 LBS.
-P, -Q, -R, -S, -T, -V
THC-2K
2000 LBS.
-P, -Q, -R, -S, -T, -V
THC-3K
3,000 LBS.
-P, -Q, -R, -S, -T, -V
THC-5K
5,000 LBS.
-P, -Q, -R, -S, -T, -V
THC-7.5
7,500 LBS.
-P, -Q, -R, -S, -T, -V
THC-10K
10,000 LBS.
-P, -Q, -R, -S, -T, -V
INSIDE HOLE DIAMETER DIMENSIONS
-P
-Q
-R
-S
-T
-V
NOMINAL
HOLE DIA.
1/8"
3/16"
1/4"
3/8"
1/2"
5/8"
ACTUAL
HOLE DIA.
.128
.193
.266
.391
.532
.656
Order Code Model
Capacity Range
Description
Price
Quantity
Add to Cart
THC-500-P
Capacity: 500 lbs
Thru Hole Load Cell
$545
THC-1K-P
Capacity: 1,000 lbs
Thru Hole Load Cell
$545
THC-2K-P
Capacity: 2,000 lbs
Thru Hole Load Cell
$545
THC-3K-P
Capacity: 3,000 lbs
Thru Hole Load Cell
$545
THC-5K-P
Capacity: 5,000 lbs
Thru Hole Load Cell
$545
THC-7.5K-P
Capacity: 7,500 lbs
Thru Hole Load Cell
$545
THC-10K-P
Capacity: 10,000 lbs
Thru Hole Load Cell
$545
Wiring Color Code (WCC1)
4 Conductor
Internal Temperature Compensation and Balance Network Not Shown
CAL-TEDS Plug & Play Option
AD9
(9 PIN "D" Series) Connector attached to the
end of a Load Cell or Torque sensor cable with a TEDS
(Transducer Electoric Data Sheet) EPPROM. Used with
a Smart Plug & Play IEEE 1451.4 Compliant instrument, (shown on right), the Load Cell and Instrument will
self calibrate. This option is a real time saver. »Learn more about Plug & Play Smart Sensors
SSI LOAD CELL DISPLAY
SMART PLUG & PLAY HAND-HELD INDICATOR WITH DATA LOGGING IEEE 1451.4 COMPLIANT
$675
»More info
DPM-3 LOAD CELL DISPLAY
SMART PLUG & PLAY
DIGITAL
PANEL MOUNT LOAD CELL METER
IEEE 1451.4 COMPLIANT
$395
»More info
SSI LOAD CELL DISPLAY
SMART PLUG & PLAY HAND-HELD
INDICATOR WITH DATA LOGGING IEEE 1451.4 COMPLIANT
$675
»More info
DPM-3 LOAD CELL DISPLAY
SMART PLUG AND PLAY DIGITAL
PANEL MOUNT LOAD CELL METER
IEEE 1451.4 COMPLIANT
Our THC Series thru-hole load cells offer an
outside
diameter of 2.00 inches and up to six
different thru-hole diameter options
per capacity
range. These load cells are manufactured from heat
treated 17-4 ph stainless
steel. The sensing element
incorporates bonded foil strain gages of the
highest
quality and are sealed for protection against most
industrial
environments.
SPECIFICATIONS
Rated Output (R.O.):
2 mV/V nominal
Nonlinearity:
0.25% of R.O.
Hysteresis:
0.25% of R.O
Nonrepeatability:
0.1% of R.O.
Zero Balance:
1.0% of R.O.
Compensated Temp. Range:
60° to 160°F
Safe Temp. Range:
-65° to 200°F
Temp. Effect on Output:
0.005% of Load/°F
Temp. Effect on Zero:
0.01% of R.O./°F
Terminal Resistance:
350 ohms nominal
Excitation Voltage:
10 VDC
Safe Overload:
150% of R.O.
Deflection Inches:
0.002 @ R.O.
MODEL
CAPACITY
LBS.
AVAILABLE INSIDE
HOLE DIAMETER
THC-250
250 LBS.
-P, -Q, -R, -S, -T, -V
THC-500
500 LBS.
-P, -Q, -R, -S, -T, -V
THC-1K
1,000 LBS.
-P, -Q, -R, -S, -T, -V
THC-2K
2000 LBS.
-P, -Q, -R, -S, -T, -V
THC-3K
3,000 LBS.
-P, -Q, -R, -S, -T, -V
THC-5K
5,000 LBS.
-P, -Q, -R, -S, -T, -V
THC-7.5
7,500 LBS.
-P, -Q, -R, -S, -T, -V
THC-10K
10,000 LBS.
-P, -Q, -R, -S, -T, -V
INSIDE HOLE DIAMETER DIMENSIONS
-P
-Q
-R
-S
-T
-V
NOMINAL
HOLE DIA.
1/8"
3/16"
1/4"
3/8"
1/2"
5/8"
ACTUAL
HOLE DIA.
.128
.193
.266
.391
.532
.656
Wiring Color Code (WCC1)
4 Conductor
Internal Temperature Compensation and Balance Network Not Shown
CAL-TEDS Plug & Play Option
AD9
(9 PIN "D" Series) Connector attached to the
end of a Load Cell or Torque sensor cable with a TEDS
(Transducer Electoric Data Sheet) EPPROM. Used with
a Smart Plug & Play IEEE 1451.4 Compliant instrument, (shown on right), the Load Cell and Instrument will
self calibrate. This option is a real time saver. »Learn more about Plug & Play Smart Sensors
SSI LOAD CELL DISPLAY
SMART PLUG & PLAY HAND-HELD INDICATOR WITH DATA LOGGING IEEE 1451.4 COMPLIANT
$675
»More info
DPM-3 LOAD CELL DISPLAY
SMART PLUG & PLAY
DIGITAL
PANEL MOUNT LOAD CELL METER
IEEE 1451.4 COMPLIANT