The TRS Series reaction torque sensors
offer long
term reliability
due to non moving
parts and state of
the art bonded foil strain
gages.
The anodized
aluminum TRS Series
is also available as a two
axis sensor,
torque
and thrust, on special request.
Whenever
possible,
the best approach
for precision
torque measurements is via reaction torque
sensing,
eliminating
high maintenance and
high cost of slip
rings,
bearings,
and brushes.
Strain Gages installed on Outside Diameter for
thru hole applications
Order Code Model
Capacity Range
Description
Price
Quantity
Add to Cart
SPECIFICATIONS
Rated Output (R.O.):
2 mV/V nominal
Nonlinearity:
0.1% of R.O.
Hysteresis:
0.1% of R.O
Nonrepeatability:
0.05% of R.O.
Zero Balance:
1.0% of R.O.
Compensated Temp. Range:
60° to 160°F
Safe Temp. Range:
-65° to 200°F
Temp. Effect on Output:
0.005% of Load/°F
Temp. Effect on Zero:
0.005% of R.O./°F
Terminal Resistance:
350 ohms nominal
Excitation Voltage:
10 VDC
Safe Overload:
150% of R.O.
DIMENSIONS (INCHES)
MODEL
CAPACITY
A
DIA.
B
C
D
E
F
G
H
WT.
LBS.
TRS-500
500
3.00
2.00
.50
1.25
.125
.28
2.25
4
0.7
TRS-1K
1,000
3.00
2.00
.50
1.25
.125
.28
2.25
4
0.7
TRS-2K
2,000
3.00
2.00
.50
1.25
.125
.28
2.25
4
0.7
TRS-5K
5,000
4.00
2.50
.50
1.50
.125
.28
3.25
8
1.2
TRS-10K
10,000
4.50
2.50
.75
1.50
.125
.28
3.75
8
2.2
TRS-20K
20,000
4.50
3.00
.75
2.00
.125
.34
3.75
8
2.2
TRS-50K
50,000
6.75
3.50
1.00
3.00
.125
.41
5.75
8
7.2
TRS-100K
100,000
6.75
3.50
1.00
3.00
.125
.41
5.75
8
7.2
MODEL
TORSIONAL
STIFFNESS
INCH LBS./RAD.
MAX
OVERHUNG
MOMENT
WxS
INCH LBS.
MAX
SHEAR
W
LBS.
MAX
THRUST
P
LBS.
LOAD CARRYING CAPACITY
P =
Thrust
W =
Weight of test device
S =
Distance to center of gravity of test unit
W x S =
Overhung moment
Do not exceed (W x S) or sheer (W), whichever value is attained first.
TRS-500
190K
500
1,500
1,500
TRS-1K
190K
500
1,500
1,500
TRS-2K
380K
1,000
2,000
2,000
TRS-5K
930K
2,000
3,000
3,000
TRS-10K
2,700K
5,000
6,000
6,000
TRS-20K
5,800K
10,000
10,000
10,000
TRS-50K
8,000K
24,000
18,000
18,000
Order Code Model
Capacity Range
Description
Price
Quantity
Add to Cart
Wiring Color Code (WCC1)
4 Conductor
Internal Temperature Compensation and Balance Network Not Shown
CAL-TEDS Plug & Play Option
AD9
(9 PIN "D" Series) Connector attached to the
end of a Load Cell or Torque sensor cable with a TEDS
(Transducer Electoric Data Sheet) EPPROM. Used with
a Smart Plug & Play IEEE 1451.4 Compliant instrument, (shown on right), the Load Cell and Instrument will
self calibrate. This option is a real time saver. »Learn more about Plug & Play Smart Sensors
SSI LOAD CELL DISPLAY
SMART PLUG & PLAY HAND-HELD INDICATOR WITH DATA LOGGING IEEE 1451.4 COMPLIANT
$675
»More info
DPM-3 LOAD CELL DISPLAY
SMART PLUG & PLAY
DIGITAL
PANEL MOUNT LOAD CELL METER
IEEE 1451.4 COMPLIANT
$395
»More info
SSI LOAD CELL DISPLAY
SMART PLUG & PLAY HAND-HELD
INDICATOR WITH DATA LOGGING IEEE 1451.4 COMPLIANT
$675
»More info
DPM-3 LOAD CELL DISPLAY
SMART PLUG AND PLAY DIGITAL
PANEL MOUNT LOAD CELL METER
IEEE 1451.4 COMPLIANT
The TRS Series reaction torque sensors
offer long
term reliability
due to non moving
parts and state of
the art bonded foil strain
gages.
The anodized
aluminum TRS Series
is also available as a two
axis sensor,
torque
and thrust, on special request.
Whenever
possible,
the best approach
for precision
torque measurements is via reaction torque
sensing,
eliminating
high maintenance and
high cost of slip
rings,
bearings,
and brushes.
Strain Gages installed on Outside Diameter for
thru hole applications
SPECIFICATIONS
Rated Output (R.O.):
2 mV/V nominal
Nonlinearity:
0.1% of R.O.
Hysteresis:
0.1% of R.O
Nonrepeatability:
0.05% of R.O.
Zero Balance:
1.0% of R.O.
Compensated Temp. Range:
60° to 160°F
Safe Temp. Range:
-65° to 200°F
Temp. Effect on Output:
0.005% of Load/°F
Temp. Effect on Zero:
0.005% of R.O./°F
Terminal Resistance:
350 ohms nominal
Excitation Voltage:
10 VDC
Safe Overload:
150% of R.O.
DIMENSIONS (INCHES)
MODEL
CAPACITY
A
DIA.
B
C
D
E
F
G
H
WT.
LBS.
TRS-500
500
3.00
2.00
.50
1.25
.125
.28
2.25
4
0.7
TRS-1K
1,000
3.00
2.00
.50
1.25
.125
.28
2.25
4
0.7
TRS-2K
2,000
3.00
2.00
.50
1.25
.125
.28
2.25
4
0.7
TRS-5K
5,000
4.00
2.50
.50
1.50
.125
.28
3.25
8
1.2
TRS-10K
10,000
4.50
2.50
.75
1.50
.125
.28
3.75
8
2.2
TRS-20K
20,000
4.50
3.00
.75
2.00
.125
.34
3.75
8
2.2
TRS-50K
50,000
6.75
3.50
1.00
3.00
.125
.41
5.75
8
7.2
TRS-100K
100,000
6.75
3.50
1.00
3.00
.125
.41
5.75
8
7.2
MODEL
TORSIONAL
STIFFNESS
INCH LBS./RAD.
MAX
OVERHUNG
MOMENT
WxS
INCH LBS.
MAX
SHEAR
W
LBS.
MAX
THRUST
P
LBS.
LOAD CARRYING CAPACITY
P =
Thrust
W =
Weight of test device
S =
Distance to center of gravity of test unit
W x S =
Overhung moment
Do not exceed (W x S) or sheer (W), whichever value is attained first.
TRS-500
190K
500
1,500
1,500
TRS-1K
190K
500
1,500
1,500
TRS-2K
380K
1,000
2,000
2,000
TRS-5K
930K
2,000
3,000
3,000
TRS-10K
2,700K
5,000
6,000
6,000
TRS-20K
5,800K
10,000
10,000
10,000
TRS-50K
8,000K
24,000
18,000
18,000
Wiring Color Code (WCC1)
4 Conductor
Internal Temperature Compensation and Balance Network Not Shown
CAL-TEDS Plug & Play Option
AD9
(9 PIN "D" Series) Connector attached to the
end of a Load Cell or Torque sensor cable with a TEDS
(Transducer Electoric Data Sheet) EPPROM. Used with
a Smart Plug & Play IEEE 1451.4 Compliant instrument, (shown on right), the Load Cell and Instrument will
self calibrate. This option is a real time saver. »Learn more about Plug & Play Smart Sensors
SSI LOAD CELL DISPLAY
SMART PLUG & PLAY HAND-HELD INDICATOR WITH DATA LOGGING IEEE 1451.4 COMPLIANT
$675
»More info
DPM-3 LOAD CELL DISPLAY
SMART PLUG & PLAY
DIGITAL
PANEL MOUNT LOAD CELL METER
IEEE 1451.4 COMPLIANT